reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
The manual I purchased was exactly what I needed to repair my Toshica television. The manual contained schematics and troubleshooting information that was very helpful.
Il download del Service Manual JVC HR 4100 non é stato eseguito
Text excerpt from page 31 (click to view)
Alignment and Adjustments
4-5 3 Speed, Aging mode & Reset mode
4-5-1 3-Speed 1. 3-Speed 1) Speed up Analog Conrtol three times and Time Speed sixty times to let line productivity be improved Analog Control. 2) Enter - Display + 3Speed Key 3) Cancel - The 3-Speed mode is cancelled in Master Power Off - Press the 3Speed Key 4) OSD : The message �3-SPEED� appears on the center of screen 5) No Signal : No AUTO OFF 2. Aging Mode 1) Enter : DISPLAY KEY -> FACTORY KEY (FACTORY MODE) -> FACTORY KEY (AGING MODE) - When the AGING mode is entered, the OSD�s are displayed at 100% SIZE WHITE. - Mute SOUND 2) Cancel - FACTORY remote conrtol -> Press the FACTORY Key - LOCAL KEY -> Use the Key MATRIX (Panel Key) - The AGING mode remains even in MASTER S/W OFF -> ON Cancel the AGING mode only in the above two cases. 3. Factory Reset 1) Run �Reset� on the Factory Menu. 2) Initialize the other user control data except the items that are adjusted in the Factory Mode. 3) Power Off in standby mode.
4-5-2 Bus Stop Mode & Remote Control Adjustment
1. Bus Stop Mode (Use a Micom Stop Pin) 1) Enter the Bus Stop Mode within 200ms when 12c Stop Port is acknowledaged �LOW�. 2) Settings when entering. - Set the screen mode �STANDARD�. - Set Bus Line Free. - Cancal the Bus Stop Mode when 12c Stop Port is acknowledged �High�. 3) Setting when cancelling - Re-load data from EEPROM and then re-set the appropriate IC. 2. Remot Control Adjustment Mode (Factory Auto Adjustment) 1) Enter the Remote Control Adjustment Mode when the remote control auto adjustment code is input. 2) Settings when entering. - Set the screen mode �STANDARD� - Set Bus Line Free. 3) Cancel the Remote Control Adjustment Mode when the usual key code is input. 4) When the code is input, write data in both E2PRM and the appropriate IC within 20ms. Interval between Code Inputs : 30ms