Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
Text excerpt from page 12 (click to view)
Alignment and Adjustments
4-3 CD
4-3-2 To Adjust Tracking Gain (PLAY mode)
1. 2. 3. Connect the GND terminal of the oscilloscope to Vref and (+) terminal to AP2. Load and play the disc While the disc is running adjust the gain with WVR1 as shown below. Normal frequency Low frequency High frequency
---0 V
---0 V
---0 V
WVR1 T.G
WVR2 WVR3 WVR4 F.G E/F. B F.B Vref
VOLT/DIV : 0.2V TIME/DIV : 2mS
VOLT/DIV : 0.2V TIME/DIV : 2mS
VOLT/DIV : 0.2V TIME/DIV : 2mS
4-3-3 To Adjust Focus Gain (PLAY mode)
1. 2. 3. Connect the GND terminal of the oscilloscope to Vref and (+) terminal to AP1. Load and play the disc While the disc is running adjust the gain with WVR2 as shown in the following figure. Normal frequency Low frequency High frequency
---250mV ---100mV ---0 V ---0 V ---100mV ---0V
VOLT/DIV : 0.1V TIME/DIV : 2mS
VOLT/DIV : 0.1V TIME/DIV : 2mS
VOLT/DIV : 0.1V TIME/DIV : 2mS
4-3-4 To Adjust E/F Balance (PLAY mode)
1. 2. 3. Set TIME/DIV of the oscilloscope to 2mS. Set Volt/DIV of the oscilloscope to 0.5V. Ground the scope input and set to DC and then set the DC range. Connect the GND terminal of the oscilloscope to Vref and (+) terminal to center to AP2. Load and play the disc. Turn WVR1 counterclockwise to the minimum value. Raise WVR3 and adjust the waveform so that its middle comes to GND of the oscilloscope (or until the upper half of waveform becomes symmetrical to the bottom half, A=B) Adjust WVR1 (arrow) for normal sound.
4-3-1 To Adjust FOCUS BIAS(STOP mode)
1. 2. 3. 4. Set Volt/Div of the oscilloscope to DC 100mV. Ground the scope input and set the waveform to 0V, DC range. Connect the GND terminal of the oscilloscope to Vref, and (+) terminal to center of AP1. Set WVR4 to 0mV.